Cobalt-60 sources
The SENTINEL range of sources and source holders caters for
most industrial applications using gamma radiography.
A
choice of isotopes provides for the widely varying
requirements demanded by different materials and site
conditions. Sources with outputs ranging from less than one
curie up to serveral hundred are available -all precision
constructed to ensure the highest possible specific activities
and smallest focal spot size.
Source exchange is available as service either on-site or
when source projectors are returned to SENTINEL for inspection
or overhaul. Sources can be shipped in the source projector on
suitable returnable transport container.
Cobalt-60 sources are constructed using compression fused
cobalt metal pellets conformed within a spherical welded
stainless steel capsule.
Characteristics
| Optimum working
thickness |
|
| steel |
50 to 500mm |
| light alloys |
150 to 450mm |
| other materials |
0.4 to 1.2g/mm² |
| Half life |
5.27 years |
| Principle gamma
energies |
1.173 &
1.333MeV |
| Output at 1 metre for
monomail equivalent activity of 37GBq (1Ci) |
| Exposure rate |
1.30 R/h |
| Air kerma rate |
3.152μ |
| Availability |
A range of sources
is normally kept stock
Pease enquire for
details. |
Source holders
Source hoders offered by SENTINEL include a comprehensive
choice of designs which match original equipment manufacturer
specifications and are fully compatible with most current
makes of gamma radiography projector.
|