Iridium-192 sources
The SENTINEL range of sources and source holders caters for
most industrial applications using gamma radiography.
A
chioce isotopes provides for the widely varying requirements
demanded by diffrent materials and site conditions. Sources
with outputs ranging from less than one curie up to serveral
hundred are available - all precision constructed to ensure
the highest possible specific activities and the smallest
focal spot sizes.
Source exchange is available as a
service either on-site or when source projectors are returned
to SENTINEL for inspection or overhaul. Sources can be shipped
in the source projector or in a suitable returnable transport
container.
Iridium-192 sources are contstructed using iridium metal
discs or pellets of uniform size in a welded stainless steel
capsule.
| Characteristics |
|
| Optimum working
thickness: |
|
| steel |
12.5 to 62.5mm |
| light alloys |
40 to 190mm |
| other materials |
0.1 to 0.5g/mm² |
| Half life |
74.0 days |
| Pinciple gamma
energies |
0.206 to 0.612MeV |
| Output at 1 metre for a nominal
equivalent activity of 37GBq (1Ci) |
|
| Exposure rate |
0.48R/h |
| Air kerna rate |
1.16μGy/s |
| |
|
| |
|
Source holders
Source holders offered by a SENTINEL include a
comprehensive chioce of designs which match
original
equipment manufacture specifications and are fully compatible
with most current makes of a gammaradiography projector.
|