Iridium-192 Source Projector - 865 Series

SENTINEL 865 source projector code TEN865

The SENTINEL 865 source projector is a certified Type B(U) package and consists of a stainless steel housing sealed against tampering or the entrance of dirt or water. The SENTINEL 865 is ideal for underwater radiography. The projector has been proven in sea water at depths up to 609m (2000ft).

The source is moved from the stored (shielded) position to the exposed position to the exposed position by a pneumatic actuator. The actuator automatically returns the source to the stored position in the event of an airline failure. The source projector incorporates a visual indication of source position on the actuating cylinder.

This projector is ideal for the radiography of steel from 13 to 64mm (1/2 to 2 1/2in) as well as light alloys over 64mm(2 1/2in) thick. Because of its lightweight design and high iridium-192 capacity, the SENTINEL 865 is particularly suited to the radiography of pipelines and heavy wall cylindrical vessels such as storage tanks, and power station component.

Features

High capacity

The use of a 8.88 TBq (240Ci) iridium-192 projector can speed up radiography operations.

Tested for underwater use

Lightweight

Only 26.8kg (59lb) for the projector.

Compact

The projector can easily pass through a 203mm (8in) diameter opening.

Self-contained

No external power supply is needed.

Safety lock

A safety lock prevents unauthorized use of the projector.

Easily shipped

The projector is a certified Type B(U) container and can be shipped loaded under I.A.E.A and U.S.N.R.C transport regulations. No overpacking or shipping barrel is required/

Remote control

7-6m (25ft) long control hoses keep operator exposures to a minimum. Control units with longer control hoses are available to special order.

Directional beam

The 60deg x 30deg radiation beam is ideal for applications where a collimator or beam limiting device would otherwise be necessary.

Control units (ordered seperately)

The SENTINEL 865 uses a dedicated control unit. For land-based radiography, the SENTINEL 86550 control unit is used. It pressurises the projector's actuating mechanism by a hand pump or an auxiliary air supply. It is equipped with a 15.2m (25ft) control hose attachment to the exposing side of the actuator. For underwater radiography, the SENTINEL 86508 control unit is used. Control units with longer hoses are available to special order.

Source assembly (ordered seperately)

Details of sources are available seperately.

Specifications

Isotope: Iridium-192

Half life: 74-0 days.

Maximum capacity: 8.88 TBq (240Ci) iridium-192.

Application:
Radiography of steel, brass and copper from 13 to 64mm (1/2 to 2 1/2in) and lighter alloys over 64mm (2 1/2 in).

Source assembly: Available seperately.

Shielding material: Depleted uranium metal, weight 18.1kg(40lb).

Dimensions: -
Length: 310mm (12 1/4in).
Diameter: 127mm (5in).
Weight: 27kg (59lb).

Packaging: Projector meets I.A.E.A., U.S.N.R.C. and U.S.D.O.T. requirements for Type B(U) packaging, certificate number USA/9187/B(U).