The Model 3009A survey meter is a specialized instrument
designed for industrial radiography. It meets the requirements
of Title 10, Part 34 of the Code of Federal Regulations
(requirements for radiographers). It features an energy
compensated, internal detector capable of accurately detecting
a broad range of exposure rates and photon energies. A
top-mounted, splash-proof speaker is provided, as well as
separate calibration controls for each range.
Features:
• Speaker for easier and more reliable surveys
•
Internal detector design protects GM tube from
rough
Handling and results in less down time
• Separate
calibration controls for each range
• Meets 10CFR34
requirements
Specifications
OPERATING CHARACTERISTICS
Radiation Detected: Gamma and
X-Rays
Accuracy: ? 20%
Energy Dependency: ? 30% 80 keV
to 1.25 MeV
Linearity: ? 20%
Operating Ranges: 0 –
10mR/h; 0 – 100mR/h; 0 - 1000mR/h(0 - 0.1 mSv/h;0 -1 mSv/h;0 -
10 mSv/h)
Exposure Rate Limit: 100 R/h (1 Sv/h)
Warm Up
Time: None
Response Time: 5 second time
constant
Environmental Effects: Temperature Range: 14°F to
122?°F (-10°C to 50°C)
Temperature Dependence: ? 15%
throughout operating range
Relative Humidity Range: 20% to
95% (non-condensing)
PHYSICAL
CHARACTERISTICS
Detector Type: Energy Compensated Halogen
Quenched GM Tube (Model 1-7301)
Detector Voltage:
920V
Readout:
Visual
Audio
2.62” round
meter
Speaker, Clicking type headset
(optional)
Controls: 4 posiion selector switch
(off,x1,x10,x100) Battery check switch, Speaker on/off
switch
Power:
Batteries One 9 volt cell for speaker
(NEDA) 1604-A or equal)
2 – “D” cells (1.5
volt)
Connectors: Phonejack for Model 3020
headset
Mechanical: Case
Ruggedized
Aluminum
Body
and cover Finish
Polyurethane
enamel Dimensions
W:
4.38” (111mm)
L: 8.75” (222mm)
H: 4.25 (108mm) Net
Weight
4 lbs.
(1.6 Kg) Shipping Weight
5 lbs.
(2.5
Kg)
ACCESSORIES
Included: Mounting: Carrying
Strap
Optional: Audio: Model 3020 headset

|