Entsys Technologies - Non-Destructive Testing and Nuclear Medicine

 
 
 
 
 
 

Survey meters

 

The Model 3009A survey meter is a specialized instrument designed for industrial radiography. It meets the requirements of Title 10, Part 34 of the Code of Federal Regulations (requirements for radiographers). It features an energy compensated, internal detector capable of accurately detecting a broad range of exposure rates and photon energies. A top-mounted, splash-proof speaker is provided, as well as separate calibration controls for each range.

Features:

• Speaker for easier and more reliable surveys
• Internal detector design protects GM tube from rough
Handling and results in less down time
• Separate calibration controls for each range
• Meets 10CFR34 requirements

Specifications

OPERATING CHARACTERISTICS
Radiation Detected: Gamma and X-Rays
Accuracy: ? 20%
Energy Dependency: ? 30% 80 keV to 1.25 MeV
Linearity: ? 20%
Operating Ranges: 0 – 10mR/h; 0 – 100mR/h; 0 - 1000mR/h(0 - 0.1 mSv/h;0 -1 mSv/h;0 - 10 mSv/h)
Exposure Rate Limit: 100 R/h (1 Sv/h)
Warm Up Time: None
Response Time: 5 second time constant
Environmental Effects: Temperature Range: 14°F to 122?°F (-10°C to 50°C)
Temperature Dependence: ? 15% throughout operating range
Relative Humidity Range: 20% to 95% (non-condensing)

PHYSICAL CHARACTERISTICS
Detector Type: Energy Compensated Halogen Quenched GM Tube (Model 1-7301)
Detector Voltage: 920V
Readout:
Visual
Audio
2.62” round meter
Speaker, Clicking type headset (optional)
Controls: 4 posiion selector switch (off,x1,x10,x100) Battery check switch, Speaker on/off switch
Power:
Batteries One 9 volt cell for speaker (NEDA) 1604-A or equal)
2 – “D” cells (1.5 volt)
Connectors: Phonejack for Model 3020 headset
Mechanical: Case
Ruggedized
Aluminum
Body and cover Finish
Polyurethane
enamel Dimensions
W: 4.38” (111mm)
L: 8.75” (222mm)
H: 4.25 (108mm) Net Weight
4 lbs.
(1.6 Kg) Shipping Weight
5 lbs.
(2.5 Kg)
ACCESSORIES
Included: Mounting: Carrying Strap
Optional: Audio: Model 3020 headset

nd 2000